Cisco MGX 8800 Series Switches

Field Notice: AXSM-E, FRSM-12-T3E3, PXM45/B and PXM45/C Anomaly with 4.0.1X Releases


May 20, 2004


Products Affected

Product

Comments

PXM45/B

Operating with 4.0.11 software.

PXM45/C

Operating with 4.0.11 software.

AXSM-32-T1E1-E

Operating with 4.0.11 software.

AXSM-16-T3E3-E

Operating with 4.0.11 software.

AXSM-8-155-E

Operating with 4.0.11 software.

AXSM-2-622-E

Operating with 4.0.11 software.

FRSM-12-T3E3

Operating with 4.0.11 software.

Problem Description

After insertion of a PXM45/B or PXM45/C into the standby slot, the standby PXM45/B or PXM45/C fails. In addition, any AXSM-E or FRSM-12-T3E3 installed in the switch will not pass user traffic.

For the purposes of this field notice, AXSM-E refers to the Product IDs listed in the Products Affected section.

Background

There are certain necessary conditions for this problem to occur.

  1. The presence of an FRSM-12-T3E3 or any model AXSM-E in MGX.

  2. At least one FRSM-12-T3E3 or AXSME-E is not passing traffic.

  3. On-Line Diagnostics is not running on the idle FRSM-12-T3E3 or AXSM-E.

  4. Physical insertion of a Standby PXM45/B or PXM45/C into MGX.

Problem Symptoms

The standby PXM45/B or PXM45/C will go to "fail" mode after resetting.

The FRSM-12-T3E3 or AXSM-E cards will generate errors towards the fabric on the standby PXM45/B or PXM45/C. User traffic will be affected.

Workaround/Solution

Workaround:

For the FRSM-12-T3E3, there is no workaround.

Enable On-Line Diagnostics on any idle AXSM-E module. User must enable at least one line and port per bay in order to enable diagnostics on an idle AXSM-E. Note that AXSM-Es that are part of an APS or Y-redundancy pair already have lines and ports configured if the Active card is configured.

Enabling On-Line Diagnostics does not interfere with redundancy and can be enabled on standby cards without negative effects.

The command for enabling On-Line Diagnostics is cnfdiag [ ] . Refer to the 4.0 user guide at MGX 8850 (PXM1E/PXM45), MGX 8950, and MGX 8830 Command Reference, Release 4.

Recovery of affected PXM45/B, PXM45/C, FRSM-12-T3E3 or AXSM-E:

If the insertion of a standby PXM45/B or PXM45/C triggered this condition, take the following steps to recover the affected cards.

AXSM-E:

  1. Issue theresetcd command on the affected AXSM-E slot. If the problem is cleared, no further action needed. The syntax is resetcd [slot] . If the symptoms do not clear, go to step 2.

  2. Physically reseat the affected AXSM-E card. If the problem is cleared, no further action is needed. Otherwise, contact Cisco.

FRSM-12-T3E3:

  1. Issue the resetcd command on the affected FRSM-12-T3E3 slot. If the problem is cleared, no further action is needed. The syntax is resetcd [slot] . If the symptoms do not clear, go to step 2.

  2. Physically reseat the affected FRSM-12-T3E3 card. If the problem is cleared, no further action is needed. Otherwise, contact Cisco.

PXM45:

Reset the PXM45/B or PXM45/C or reseat the PXM45/B or PXM45/C to recover from failed state.

Solution:

Upgrade MGX software to later releases of 4.0.1x or to 5.0.00 or later 5.0 releases. Monitor CSCed94385 (registered customers only) for releases that fix this bug.

DDTS

To follow the bug ID link below and see detailed bug information, you must be a registered user and you must be logged in.

DDTS

Description

CSCed94385 (registered customers only)

Xbar errors on slots with AXSM-E cards

CSCdx24721 (registered customers only)

dspswalms reporting xbar core and slot bw alarms.