Guest

Cisco Unified MeetingPlace

Field Notice: MeetingPlace Server Outdial Does Not Work Due to Timer Leak


May 17, 2004


Products Affected

Product

Comments

Cisco MeetingPlace Servers

Versions: 4.3.1a, 5.0.2q, 5.1.0x, and 5.1.1b

Problem Description

Not able to use the "CALL ME" feature from the Cisco MeetingPlace Web interface and consistently received the following alarm:

10/03 16:04:02 MIN 0x900fc 0/3, "cpmidstatemachine.c", 2483 (0x3, 0, 0xc, 0x7f20)
     ()Failed timer AddRequest, port=3,fConf=0,err=c

ALL T1 PRI servers should have this hot fix applied.

Problem Symptoms

Meeting attendee cannot outdial.

Workaround/Solution

WORKAROUND:

None

SOLUTION:

A cpserver hot fix is available for 4.3.1g, 5.0.2ab and 5.1.1e. Contact the Cisco MeetingPlace Technical Assistance Center to apply this hot fix.

For More Information

If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods:

Receive Email Notification For New Field Notices