Cisco Unified MeetingPlace

Field Notice: MeetingPlace Server - "Insufficient Ports" Scheduling Failure Message Shows Incorrect Number of Available Ports


May 17, 2004


Products Affected

Product

Comments

Cisco MeetingPlace Server 8112 (M3)

Versions: 5.1.0x and 5.1.1b

Problem Description

When scheduling fails due to not enough ports, the error message shows an incorrect number of available ports.

For instance, there are 4 ports available and we try to schedule a 6 port meeting.

5179 - not enough port for requested operation
     13074 - number of ports available at specified time: 0

So even though there are 4 ports available, it shows 0 available.

Problem Symptoms

Scheduler would not know the actual number of ports available to schedule a meeting.

Workaround/Solution

WORKAROUND:

Decrease the number of ports until it schedules successfully.

SOLUTION:

A 5.1.1c ConfSchd hot fix is available. Contact the Cisco MeetingPlace Technical Assistance Center to apply this hot fix.

For More Information

If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods: