Cisco Unified MeetingPlace

Field Notice: Unable to Start a Reservationless Meeting if Your Profile Number is Longer Than Nine Digits


May 24, 2004


Products Affected

Product

Comments

Cisco MeetingPlace Server 8112 (M3)

5.0.2q

Problem Description

Note: This Field Notice is a legacy Latitude Field Notice that has been converted to the Cisco format so the information would remain available to their customers.

Users with profile numbers longer than 9 digits will not be able to start a reservationless meeting. When they attempt to start a reservationless meeting, they will get the following prompt and get disconnected from the system:

"We are unable to start a meeting at this time. Please try again later"

The error log ("errorlog -s info -l") will show the following statement

01/10 11:48:01 INFO 0x30129 0/8, "vuiactconf2.cc", 5910 (0x144e, 0x38, 0x144e,0)

Personal meeting failed because could not schedule: Erc 5198

Where Erc 5198 translates to "Specified meeting ID length greater than maximum allowed".

Problem Symptoms

Users with profile number longer than 9 digits will not be able to start a reservationless meeting.

Workaround/Solution

WORKAROUND

Customers who use the reservationless feature should limit the length of their users' profile number to 9 digits or less.

SOLUTION

This will be fixed in the next major release.