Guest

Cisco ONS 15800 Series DWDM Platforms

Field Notice: *Expired* FN - 18487 - ONS 15800 and 15801 Revision 1.6.0 and 1.4.0 WCMs, LEMs and RXTs Need a Specific Firmware Upgrade Procedure


Revised December 13, 2007

March 13, 2002

NOTICE:

THIS FIELD NOTICE HAS BEEN EXPIRED AND IS NO LONGER MAINTAINED OR UPDATED BY CISCO.

THIS FIELD NOTICE IS PROVIDED ON AN "AS IS" BASIS AND DOES NOT IMPLY ANY KIND OF GUARANTEE, WARRANTY OR SUPPORT. USE OF THE INFORMATION ON THIS FIELD NOTICE OR MATERIALS LINKED FROM THIS FIELD NOTICE IS AT YOUR OWN RISK. CISCO RESERVES THE RIGHT TO CHANGE OR UPDATE THIS FIELD NOTICE AT ANY TIME.


Products Affected

Product

Comments

LEM-EM-F2.5G

Application version: 1.0.0; SCC Slave version: 2.1.0

WCM-EM-F2.5G

Application version: 1.0.0; SCC Slave version: 2.1.0

RXT-EM-F2.5G

Application version: 1.0.0; SCC Slave version: 2.1.0

LEM-10G-F

Application version: 1.0.1; SCC Slave version: 2.1.0

WCM-10G-F

Application version: 1.0.1; SCC Slave version: 2.1.0

RXT-10G-F

Application version: 1.0.1; SCC Slave version: 2.1.0

Problem Description

After a firmware upgrade, Cisco Photonics Toolkit (PTK) can lose the control of some of the previousy upgraded units. This will only happen in the following cases.

  • Firmware upgrade from Cisco ONS 15800 Release 1.6.0 or Cisco ONS 15801 Release 1.4.0 (Spring Base Release) to any Spring sustaining release.

  • Firmware upgrade from Cisco ONS 15800 Release 1.6.0 or Cisco ONS 15801 Release 1.4.0 (Spring Base Release) to any Cisco ONS 15800 or 15801 Release 2.0 (Emerald) release.

Note: An upgrade from one Spring sustaining release to another is not affected.

Note: Applicability is limited to the above specified units.

Background

The upgrade procedure described is not traffic affecting. All the steps described below are part of the standard Firmware Upgrade Procedure as described in the Cisco PTK Software Administration Manual.

Problem Symptoms

Recently upgraded units are neither visible nor manageable from the craft terminal after a reset.

Workaround/Solution

The procedure, described within the paragraphs below, is intended for a single Network Element (NE).

It is mandatory to use the following sequence of steps.

  1. Download (Multiple Download if the node has more than one board to be downloaded) through Cisco PTK, the new application firmware version on modules listed above.

  2. On each card, activate the firmware item downloaded in step 1 issuing the Cisco PTK board reset command.

  3. Download (Multiple Download if the node has more than one board to be downloaded), through Cisco PTK, a new Slave SCC firmware version on modules listed above.

  4. Activate the firmware item downloaded in step 3 on each card issuing the Cisco PTK board reset command.

DDTS

To follow the bug ID link below and see detailed bug information, you must be a registered user and you must be logged in.

DDTS

Description

CSCuk28515 (registered customers only)

Lost units after firmware upgrade

For More Information

If you require further assistance, or if you have any further questions regarding this field notice, please contact the Cisco Systems Technical Assistance Center (TAC) by one of the following methods: