Configuring SNMP Trap Servers
You can specify the IP address, port, enabled traps for multiple SNMP trap servers to which the Media Server sends SNMP traps, and events to display in the Event Log tab from the Alert Indications section of the Settings tab.
Procedure
- In the MSA interface, on the sidebar, click MCU.
- Click the Settings tab.
- Click Alert Indications.
- Click Add in the SNMP Traps Server section.
- Enter the IP address for the SNMP trap server in the SNMP Trap server address field in the SNMP Trap Server Properties window.
- Enter the port of the SNMP trap server in the Port field. The default port for SNMP servers is 162.
- To disable a trap, follow these steps:
- To enable a trap, follow these steps:
- Click Upload to save your settings.
The system displays the configured SNMP trap server in the SNMP Trap Servers section.
Copyright © 2002-2008, Cisco Systems, Inc. All rights reserved.