Enabling Cisco Unified MeetingPlace 3500 Series Media Server Alert Indications and Setting Security Levels
You can configure which alerts will be enabled and set a severity level for each one from the Alert Indications section of the Settings tab.
Table 2-4 lists alert indications as well as the SNMP trap associated with them.
Table 2-5 lists the structure of the standard coldStart and warmStart traps (as defined in RFC 1907) and the standard linkDown and linkUp traps (as defined in RFC 1573).
Procedure
- In the MSA interface, on the sidebar, click MCU.
- Click the Settings tab.
- Click Alert Indications.
- Select the events that you want to display in the event log from the Enabled column in the Events section.
- Choose one of the following severities in the Severity column for each event that you enable:
- Cleared (0) One or more previously reported alarms have been cleared.
- Information (1)Notification of a non-erroneous event.
- Critical (2)A service-affecting event has occurred and requires immediate corrective action.
- Major (3)A service-affecting event has occurred and requires corrective action to prevent the condition becoming more serious.
- Minor (4)A non-service-affecting event has occurred and requires corrective action to prevent the condition becoming more serious.
- Warning (5)A potential or impending service-affecting event has been detected, but no significant events have occurred yet. Action should be taken to further diagnose and correct the problems to prevent the condition becoming more serious.
Tip You can click Select All to select all events or Clear All to clear all events.